ATEC Sampling Ball Valve Type PRF

Due to the angled stem design and the direct mounting to the vessel bottom flange, the ball is flush with the vessel inner wall. For a seamless, flush connection, the contour of the ball valve insert can be adapted to the radius of the vessel bottom to reduce so-called dirty corners. The usual dead spaces between ball and housing are filled by sealing half shells and prevent the product residues in the dead spaces from crystallizing, caking together and thus impairing the function. For a clean and easy removal of solid products, a screw conveyor is mounted on the ball valve by means of a quick-action connection.

[Translate to English:] Typ PRF

Technical Data :

Nominal sizes

DN 15 - 80

Max. operating pressure

Up to 40 bar

Temperature range

-196°C to +500°C

Tank connection

Vessel bottom flange acc.to  DIN 28117 / DIN 28140

Sampling connection

Sample bottle with glass thread to DIN 168

Milk thread according to DIN 11851

Clamping connection acc. to DIN 32676

Documentation

DEFREN
Brochure

Application

Chemical & Pharmaceutical
Food & Beverages